Lakos SandMasters Manuale Utente

Navigare online o scaricare Manuale Utente per Per casa Lakos SandMasters. LAKOS SandMasters User Manual [fr] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 2
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
(See reverse for additional instructions)
CLAUDE LAVAL CORPORATION FRESNO, CALIFORNIA U.S.A
From
Pump
Pressure
Tank
LAKOS
SANDMASTER
Valve
Sand Purge
IMPORTANT: Install SandMaster between
the pump and pressure tank.
Flow to house
Close-Up of Optional
LAKOS Mounting Bracket
Check Valve
Pressure Gauges
(recommended)
Pressure Switch
For effective sand removal, SandMaster must be operated within the recommended flow range for each model (see
product label). Pipe size is not a factor in model selection. Use pipe reduction fittings as necessary to connect to
existing piping. Minimum inlet pressure should be at least 15 psi (1 bar). If operating a variable-flow pump,
separator’s performance will be affected at flows below the recommended range for any model; LAKOS recommends
that the separator be sized for the highest expected flow rate (or consult factory for additional considerations). Read
all instructions before proceeding.
Installation Placement
1. Separator must be placed between the pump and pressure tank of a residential water well system.
2. Check valve must be between the pump and separator.
3. Pressure switch must be between the separator and the pressure tank.
4. Any tees or diversions of pump discharge flow (such as to sprinklers or other needs) should be installed after
the separator’s outlet.
Installation Procedures
1. Remove plastic caps from the inlet, outlet and purge connections.
2. Install separator in the near upright position. For best results, allow at least five pipe diameters of straight
pipe to and from the separator’s inlet and outlet connections.
3. Support the separator’s weight independently from the inlet/outlet piping. A LAKOS Mounting Bracket Kit is
recommended, but may be substituted with similar hardware.
SANDMASTER SERIES
Installation & Operating Instructions
FOR RESIDENTIAL WATER WELL SYSTEMS ONLY
Vedere la pagina 0
1 2

Sommario

Pagina 1 - SANDMASTER SERIES

(See reverse for additional instructions)CLAUDE LAVAL CORPORATION FRESNO, CALIFORNIA U.S.AFromPumpPressureTankLAKOSSANDMASTERValveSand PurgeIMPORTANT:

Pagina 2 - Email: [email protected]

4. Pressure gauges are recommended at the inlet and outlet of the separator. A pressure differential reading of 5-15 psi (0.3-1.0 bar) confirms th

Commenti su questo manuale

Nessun commento